Torque Guidelines Steel Construction Washers

Note that the torque guidelines below only apply to HV bolts with NLSC washers.

 
Bolt size Product name Reduced preload force Modified torque method Modified combined method
[torque + angle]
Securing effect
    Fp, C, SC*
[kN]
torque 
MA, SC
[Nm]
pre-torque 
MA, MKV, SC
[Nm]
minimum torque 
MA, SC, min
[Nm]


M12

NL12SC 45 130 100 80


M16

NL16SC 90 330 250 200


M20

NL20SC 145 660 490 360


M22

NL22SC 170 850 640 520


M24

NL24SC 200 1100 825 640


M27

NL27SC 260 1600 1220 1000


M30

NL30SC 315 2150 1650 1320


M36

NL36SC 460 3750 2800 2240

*Tightening conditions are specified in ETA-13/0246 for HV bolts, grade 10.9.

 

Required angle of further rotation

Clamp length angle part tum
t < 2d 45° 1/8
2d ≤ t < 6d 60° 1/6
6d ≤ t ≤ 10d 90° 1/4
10d < t No recommendations