Specification | |
Weight | 2.04kg (including batteries) |
Size | 216mm x 165mm x 70mm |
Keyboard | Membrane switch pad with 21 tactile keys |
Power Source | Lithium Ion Pack 10.8V, 2 amp 18hrs typical operation. Emergency battery backup. 6 x 1.5V alkaline, 1.2V AA NIMH or other equivalent power sources. |
Memory | 4 Gb internal & up to 64 Gb external SD Slot. |
Data Output | USB Direct 1.1 PC Connectivity and RS232 PC serial interface. |
TRANSDUCER DATA & SELECTION
There are several things to consider when deciding which transducer to use:
- The crystal diameter should be completely in contact with the bolt end surface.
- The outside diameter should be clear of any obstruction.
- The frequency should be chosen to suit the bolt length.
- The larger the diameter the stronger the signal and therefore better results are obtained by using the largest size transducer that will fit on the bolt.
- Boltight recommends the 3/8” diameter, 5MHz transducer as the best general purpose covering 90% or more of typical bolting applications.
Size (diameter) | Frequency | Application |
1/8” (3.1mm) | 5 Mhz | General Purpose |
1/8” (3.1mm) | 10 Mhz | Hi-resolution/short Bolts |
3/16” (4.7mm) | 5Mhz | General Purpose |
1/4” (6.3mm) | 2.25 Mhz | Long Bolts |
1/4” (6.3mm) | 5 Mhz | General Purpose |
1/4” (6.3mm) | 10 Mhz | Hi-resolution/Short Bolts |
3/8” (9.5mm) | 2.25 Mhz | Long Bolts |
3/8” (9.5mm) | 5 Mhz | General Purpose |
1/2” (12.7mm) | 2.25 Mhz | Long Bolts |
1/2” (12.7mm) | 5 Mhz | General Purpose |
3/4” (19.0mm) | 2.25 Mhz | Long Bolts |
3/4” (19.0mm) | 5 Mhz | General Purpose |
MAGNETIC TRANSDUCERS
Diameter reference | Outside diameter |
1/8” (3.1mm) | 0.38” (9.6mm) |
3/16” (4.7mm) | 0.38” (9.6mm) |
1/4” (6.3mm) | 0.75” (19.0mm) |
3/8” (9.5mm) | 0.81” (20.5mm) |
1/2” (12.7mm) | 1“ (25.4mm) |
3/4” (19.0mm) | 1.21” (30.7mm) |
NON-MAGNETIC TRANSDUCERS
Diameter reference | Outside diameter |
1/8” (3.1mm) | 0.23” (5.8mm) |
1/4” (6.3mm) | 0.355” (9.0mm) |
1/2” (12.7mm) | 0.605” (15.3mm) |
Download software:
Boltight Echometer Software Version 4.06c (Windows)
Boltight Echometer Software Version 4.06c (MacOSX)